DIG-IP-STN (Digital IP Station)
NOTE:
This nondestructive test runs due to in-line errors, during periodic and
schedule maintenance, and on demand.
Table 10-203. TEST #1373 Signaling Path PING Test
Error
Test
Code
Result
2100
ABORT
2500
ABORT
1003
FAIL
1007
FAIL
PASS
555-233-123
Description/Recommendation
Could not locate the necessary system resources to run this
test.
Retry the command at 1-minute intervals, up to 5 times.
Escalate if the problem persists.
Internal system error
Retry the command at 1-minute intervals, up to 3 times.
Escalate if the problem persists.
Ping to the destination failed.
Retry the command at 1-minute intervals, up to 3 times.
Investigate any C-LAN ethernet port errors.
The system could not PING the registered endpoint via the
C-LAN.
Verify that at least one destination reachable through this port.
PING this destination (ping ip-address xxx.xxx.xxx.xxx).
If the PING to any destination is successful through this port, the
link is up.
If PING to all destinations fail, test the C-LAN port (test port
UUCSSpp short) and follow repair procedures for Session
Status Test (#1286) failures.
If only this station cannot be pinged:
Make sure the PC is up
Make sure the PC has a network connection (ethernet or dialup)
Check the ethernet cabling
The system can successfully send IP packets to the registered
endpoint from the C-LAN.
Continued on next page
Issue 4 May 2002
10-555