Maintenance Object Repair Procedures
Error Log Entries and Test to Clear Values
Table 10-145. CLAN-BD Error Log Entries
Error
Aux
Type
Data
1(a)
0
18 (b)
0
217 (c)
0
None
257
65535
Control Channel
Loop Test (#52)
257 (d)
513 (e)
4352-
4357
769 (f)
4358
1293 to
Any
1295 (g)
1537(h)
Any
1794 (i)
1798 (j)
2049 (k)
Packet Interface
Test (#598)
2305
2306 (l)
2561 to
Any
2668 (m)
2817
Congestion Query
2819 (n)
Test (#600)
3073 (o)
Link Status Test
(#601)
3330 (p)
3586 (q)
3999 (q)
Any
None
3840 (r)
4096-
4102
3841
3843 (s)
10-394
Issue 4 May 2002
Alarm
Associated Test
Level
MINOR
WARNING
WARNING
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
MINOR
On/Off
Board
Test to Clear Value
ON
OFF
release board UUCSS
ON
ON
test board UUCSS l r 20
ON
ON
reset board UUCSS
ON
ON
ON
test board UUCSS l r 3
ON
test board UUCSS s r 3
ON
test board UUCSS s
ON
reset board UUCSS