Avaya Definity SI Maintenance Manual page 936

Table of Contents

Advertisement

Maintenance Object Repair Procedures
2. Performing a test board long when the circuit pack is in this state
3. The save/restore announcements command times out with:
The Announcement circuit pack lock-up can be cleared remotely by
performing a soft reset to the circuit pack:
Super Frame Match Inquiry Test (#211)
The super frame is a means by which the SP synchronizes with the 140AY device
on the Announcement circuit pack. If the super frame is not synchronized, the SP
is not able to properly process record/playback requests. Both the SP and the
hardware generate a super frame pulse. When these two pulses are out of synch,
the SP sets a flag to indicate the mismatch. When this test is run, the state of this
flag is returned.
Table 10-49. TEST #211 Super Frame Match Inquiry
Error
Code
2000
2100
10-150
Issue 4 May 2002
yields the following abort codes:
Ports 1 AND 9 abort Test #206 with code 1024
Ports 1 AND 9 abort Test #205 with code 2000
Board level Tests #209 and #210 abort with code 1024
Error encountered, can't complete request
busyout board PCSS (this command drops all calls in progress on
the Announcement circuit pack)
reset circuit pack using the reset board PCSS command
release circuit pack using the release board PCSS command
Test
Result
ABORT
Response to the test request was not received within the
allowable time period. If Error Type 1538 is present in the Error
Log, follow the maintenance strategy recommended for this
Error Type.
ABORT
Could not allocate the necessary system resources to run this
test.
ABORT
Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Description/Recommendation
Continued on next page
555-233-123

Advertisement

Table of Contents
loading