Maintenance Object Repair Procedures
Table 10-102. ATM Board Framer Looparound Test (#1260)
Error
Test
Code
Result
1002
ABORT
1003
ABORT
1015
ABORT
1033
ABORT
1139
ABORT
1141
ABORT
1144
ABORT
10-250
Issue 4 May 2002
Description/Recommendation
Time slots could not be allocated. Traffic could be heavy or time
slots could be out-of-service.
Run display errors, and perform repairs associated with
TDM-BUS errors.
Retry the command up to 3 times at 1-minute intervals.
Tone receiver could not be allocated.
Run display errors, and perform the repairs associated with
TTR-LEV and TONE-PT errors.
The test cannot run unless there is at least one Tone Detector
available on the network that holds the ATM-TRK circuit pack.
Retry the command up to 3 times at 1-minute intervals.
ATM-TRK circuit pack not busied out
Busyout the ATM circuit pack.
Rerun the command.
ATM-TRK circuit pack not found
See if the switch can see the circuit pack. Run status Trunk
Group.
Retry the command.
Major alarm on the EPN packet bus
Run display alarms, and perform the repairs associated with
PKT-BUS errors.
Run display errors, and perform the repairs associated with
PKT-BUS errors.
Retry the command.
Packet-interface circuit pack out of service
See PKT-INT (Packet Interface Circuit Pack).
Major alarm on the PPN packet bus
Run display alarms, and perform the repairs associated with
PKT-BUS.
Run display errors, and perform the repairs associated with
PKT-BUS.
Retry the command.