Maintenance Object Repair Procedures
Table 10-181. TEST #109 Data Channel Remote Maintenance Loop Around
Test — Continued
Error
Code
1000
ABORT
10-492
Issue 4 May 2002
Test
Result
Error Code of 1000 can mean one of several things:
a. Target DATA-CHL is busy and, therefore, not available for
use.
b. No other DATA-CHLs are administered and, therefore,
not available to place the call to the target DATA-CHL.
c. All other DATA-CHLs are busy and, therefore, not
available to place the call to the target DATA-CHL.
d. Could not allocate the necessary system resources to run
this test.
e. Internal system error.
If the results of Tests #110 and #111 are both PASS, then there
is a high probability that the target DATA-CHL is not defective.
Proceed with the remaining steps only if it is necessary to
completely test the target DATA-CHL:
1. Determine if errors exist on links using target DATA-CHL
(status link).
2. If there are no errors, busyout the links (busyout link).
3. Determine if no other DATA-CHLs are administered (list
data-module).
4. If no other DATA-CHLs are administered, administer at least
one.
5. Determine if links exist on all non-target DATA-CHLs (status
link).
6. If links exist on all DATA-CHLs, busyout the links (busyout
link).
7. Retry the command at 1-minute intervals, up to 5 times.
8. Restore any busied out links.
Description/Recommendation
Continued on next page