Bri-Set, Asai-Adj, Bri-Dat - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Object Repair Procedures

BRI-SET, ASAI-ADJ, BRI-DAT

MO Name (in
Alarm Log)
Alarm Level
BRI-SET
WARNING
ASAI-ADJ
MAJOR
ASAI-ADJ
MAJOR
ASAI-ADJ
WARNING
ATT-ADJ
MAJOR
ATT-ADJ
MAJOR
ATT-ADJ
WARNING
LGATE-AJ
MAJOR
LGATE-AJ
MAJOR
LGATE-AJ
WARNING
ATTE-AJ
MAJOR
ATTE-AJ
MAJOR
ATTE-AJ
WARNING
BRI-DAT
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (A,
B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located (01, 02,
etc.); and pp is the 2-digit port number (for example, 01). The alternate name field contains the
extension of the endpoint. This field is used to distinguish between endpoints on the same port.
2
The alarm level for ASAI and Avaya adjuncts may be administered using the set options command.
The alarm level can be set independently for Off-Board and On-Board alarms to WARNING,
MINOR, or MAJOR for all ASAI and Avaya adjuncts in the system.
3
Alarming for an ASAI and Avaya adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the endpoint.
Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included
in Chapter 9, "Packet Bus Fault Isolation and Correction". This flowchart,
along with the other information presented in the chapter, can help in
resolving problems that involve more than a single station or circuit pack.
Whenever the repair procedures for this Maintenance Object refer to Packet
Bus and/or Packet Control maintenance, be sure to reference Chapter 9,
"Packet Bus Fault Isolation and Correction" in addition to the relevant MO
documentation.
10-292
Issue 4 May 2002
Initial Command to Run
2
test station extension l,
test data-module extension
2
test station extension
2
test data-module extension
3
test data-module extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
2
test station extension
2
test station extension
3
test station extension
test data-module
1
Full Name of MO
ISDN-BRI Set
ASAI-Adjunct
ASAI-Adjunct
ASAI-Adjunct
Avaya-Adjunct
Avaya-Adjunct
Avaya-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet ASAI-Adjunct
Ethernet Avaya-Adjunct
Ethernet Avaya-Adjunct
Ethernet Avaya-Adjunct
555-233-123

Advertisement

Table of Contents
loading

Table of Contents