Clear the OTDR-BASELINE-R-EXCEEDED-TX Alarm

Clear the OTDR-BASELINE-R-EXCEEDED-TX Alarm
The alarm is cleared automatically when one of the following conditions is satisfied:
• The reflectance event causing the alarm disappears.
• The reflectance event is below the threshold.
• The absolute threshold check is activated.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-FAST-FAR-END-IN-PROGRESS
Default Severity: Minor (MN)
Logical Object: EQUIPMENT
The OTDR-FAST-FAR-END-IN-PROGRESS alarm is raised when a fast scan is started on the remote side.
Clear the OTDR-FAST-FAR-END-IN-PROGRESS Alarm
Step 1
Wait until the scan on the remote side is completed. The time varies depending on the type of scan.
Step 2
Alternatively, stop the scan by navigating to: Maintenance->DWDM->OTDR; select the side where the scan is ongoing
and click Cancel. The scan is stopped on both the sides.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-FAST-SCAN-IN-PROGRESS-RX
Default Severities: Minor (MI), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) Fast Scan In Progress Rx alarm is raised when the fast
OTDR scan starts in the Rx direction.
Clear the OTDR-FAST-SCAN-IN-PROGRESS-RX Alarm
Step 1
This alarm is cleared automatically when the fast OTDR scan in the RX direction is complete.