Auto-Sense-Dsbld - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

AUTO-SENSE-DSBLD

AUTO-SENSE-DSBLD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: PPM
The AUTO-SENSE-DSBLD alarm is raised when the port is configured as an AUTO port, but auto-sensing
is disabled.
Clear the AUTO-SENSE-DSBLD Alarm
SUMMARY STEPS
1. Clear the AUTO-SENSE-DSBLD alarm with either of these procedures:
DETAILED STEPS
Clear the AUTO-SENSE-DSBLD alarm with either of these procedures:
a) Enable auto-sensing.
1. Login to CTC.
2. In node view (single-shelf mode) or shelf view (multishelf view), double-click the AR_MXP or AR_XP card
where you want to enable auto-sensing.
3. Click the Provisioning > Line > Auto Ports tabs.
4. Check the Auto Sensing check box.
b) Delete the auto port.
1. Login to CTC.
2. In node view (single-shelf mode) or shelf view (multishelf view), double-click the AR_MXP or AR_XP card
where you want to delete the auto port.
3. Click the Provisioning > Pluggable Port Modules tabs.
4. In the Pluggable Port Modules area, select the auto PPM that you want to delete and click Delete.
5. Click Yes. The auto port is deleted.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
AUTORESET
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
132
http://www.cisco.com/c/en/us/support/index.html
Alarm Troubleshooting

Advertisement

Table of Contents
loading

Table of Contents