Error Messages
Error/Warning
ID
EID-2114
EID-2115
EID-2116
EID-2118
EID-2119
EID-2120
EID-2121
EID-2122
EID-2123
EID-2124
EID-2125
EID-2126
Error/Warning Message
A card communication failure occurred during the
operation.
An error occurred during the operation. {0}
The extension byte setting for the ring is invalid. {0}
The ring cannot be deleted. A protection operation is
set. All protection operations must be clear for ring to
be deleted.
{0} cannot be deleted because a protection switch is in
effect. Please clear any protection operations, ensure
that the reversion time is not "never" and allow any
protection switches to clear before trying again.
The following nodes could not be unprovisioned {0}
Therefore you will need to delete this {1} again later.
The ring cannot be upgraded. {0}
The ring speed for is inadequate for the upgrade
procedure. Only {0} (or higher) {1} can be upgraded
to four-fiber.
Verify that the following nodes have at least two
in-service ports with the same speed as the two-fiber
{0}. The ports cannot serve as timing references, and
they cannot have DCC terminations or overhead
circuits. {1}
You cannot add this span because it is connected to a
node that already has the east and west ports defined.
You cannot add this span as it would cause a single
card to host both the east span and the west span. A
card cannot protect itself.
An error occurred while provisioning the OSPF area.
{0}
Description
This error can occur during an attempt
to apply a BLSR protection operation
to a line.
There was an error in applying the
specified operation.
The extension byte set for the
specified ring is invalid.
Clear all the protection operations for
the ring before deleting it.
Clear all protection operations or
switches before deleting the ring.
The specified nodes could not be
unprovisioned. Try deleting this BLSR
or MS-SPRing later.
CTC cannot upgrade the specified
ring.
You have selected an incorrect ring
speed for upgrade. Only rings within
the specified parameters can be
upgraded to 4-fiber BLSR.
Nonupgradable nodes. Verify that the
specified nodes have at least two
IS-NR ports with the same speed as
the 2-fiber BLSR. The specified ports
cannot serve as a timing reference, and
they cannot have data communications
channel (DCC) terminations or
overhead circuits.
Refer to the error message text.
Refer to the error message text.
There is an Open Shortest Path First
(OSPF) area error.