Alarm Troubleshooting

Clear the OTDR-ORL-TRAINING-FAILED-RX Alarm

Execute the scan in the RX direction.
Note
If the scan shows high reflections, clean the connectors where the reflections are too high or change the
corresponding patchcords.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ORL-TRAINING-FAILED-TX
Default Severity: Minor (MN)
Logical Object: EQUIPMENT
The OTDR-ORL-TRAINING-FAILED-TX alarm is raised if the training phase cannot find valid calibration
data.
Clear the OTDR-ORL-TRAINING-FAILED-TX Alarm
Execute the scan in the TX direction.
If the scan shows high reflections, clean the connectors where the reflections are too high or change the
Note
corresponding patchcords.
If the alarm does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-ORL-TRAINING-IN-PROGRESS-RX
Default Severity: NA
Logical Object: EQUIPMENT
The OTDR-ORL-TRAINING-IN-PROGRESS-RX alarm is raised if the ORL is started in the fast mode on
the Rx side.
Clear the OTDR-ORL-TRAINING-IN-PROGRESS-RX Alarm
Wait until ORL training is completed in the Rx side. ORL training takes 10 seconds.