SPAN-NOT-MEASURED

SPAN-NOT-MEASURED
The SPAN-NOT-MEASURED condition is raised when a node cannot perform the span loss verification as
it cannot communicate with its peer at the other end of the span.
SWFTDOWNFAIL
The Software Download Failed (SFTDOWN-FAIL) condition occurs when the system fails to download the
required software.
An incorrect input that points to the wrong place or file, network issues, or a bad (corrupt) package can cause
this failure. Retrying the operation with the correct name/location will usually succeed. If network issues
persist, you must contact the network lab support. If the package is corrupt, contact the Cisco Technical
Assistance Center (TAC) (1 800 553-2447) for assistance.
USER-LOCKOUT
The User Locked Out (USER-LOCKOUT) condition occurs when the system locks an account because of a
failed login attempt. To proceed, the administrator must unlock the account or the lockout time must expire.
USER-LOGIN
The Login of User (USER-LOGIN) occurs when you begin a new session by verifying your user ID and
password.
This transient condition does not result in a standing condition.
USER-LOGOUT
The Logout of User (USER-LOGOUT) condition occurs when you stop a login session by logging out of
your account.
This transient condition does not result in a standing condition.
WKSWBK
The Switched Back to Working (WKSWBK) condition occurs when traffic switches back to the working port
or card in a nonrevertive protection group.
This transient condition does not result in a standing condition.
WKSWPR
The Switched to Protection (WKSWPR) condition occurs when traffic switches to the protect port or card in
a nonrevertive protection group.
This transient condition does not result in a standing condition.