Clear The Syncpri Alarm - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

Alarm Troubleshooting
A Loss of Timing on Primary Reference alarm occurs when the NCS system loses the primary timing source
(reference 1). The NCS system uses three ranked timing references. The timing references are typically two
BITS-level or line-level sources and an internal reference. If SYNCPRI occurs, the NCS system should switch
to its secondary timing source (reference 2). Switching to the secondary timing source also triggers the
SWTOSEC , on page 408

Clear the SYNCPRI Alarm

SUMMARY STEPS
1. In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Timing >
General tabs.
2. Verify the current configuration for REF-1 of the NE Reference.
3. If the primary timing reference is a BITS input, complete the
procedure.
4. If the primary reference clock is an incoming port on the NCS system, complete the Clear the LOS
(OCN/STMN) Alarm procedure located in the Alarm Troubleshooting chapter of the Troubleshooting
guide.
DETAILED STEPS
Step 1
In node view (single-shelf mode) or shelf view (multishelf mode), click the Provisioning > Timing > General tabs.
Step 2
Verify the current configuration for REF-1 of the NE Reference.
Step 3
If the primary timing reference is a BITS input, complete the
Step 4
If the primary reference clock is an incoming port on the NCS system, complete the Clear the LOS (OCN/STMN) Alarm
procedure located in the Alarm Troubleshooting chapter of the Troubleshooting guide.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
en/us/support/web/tsd-cisco-worldwide-contacts.html
your country.
SYNCSEC
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: EXT-SREF, NE-SREF
A Loss of Timing on Secondary Reference alarm occurs when the ONS system loses the secondary timing
source (reference 2). If SYNCSEC occurs, the ONS system should switch to a third timing source (reference
3) to obtain valid timing for the ONS system. Switching to a third timing source also triggers the
, on page 408
alarm.
alarm.
Clear the LOS (BITS) Alarm, on page 274
Clear the LOS (BITS) Alarm, on page 274
for more information or log into
to obtain a directory of toll-free Technical Support numbers for
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
Clear the SYNCPRI Alarm
procedure.
http://www.cisco.com/c/
SWTOTHIRD
411