Pwr-Con-Lmt - Cisco NCS 2000 series Troubleshooting Manual

Hide thumbs Also See for NCS 2000 series:
Table of Contents

Advertisement

Alarm Troubleshooting

PWR-CON-LMT

Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Power Consumption Limit Has Crossed (PWR-CON-LMT) condition is raised at the shelf level when
the total power consumption of the shelf equals or exceeds the maximum power. This alarm is applicable for
all the following AC and DC power supply modules of NCS 2006 shelf and AC and DC power supply module
of NCS 2015 shelf.
• NCS2006-DC20
• NCS2006-AC
• NCS2006-DC
• NCS2006-DC40
Clear the PWR-CON-LMT Alarm
SUMMARY STEPS
1. Remove the card that caused the alarm from the shelf and de-provision it in CTC.
DETAILED STEPS
Remove the card that caused the alarm from the shelf and de-provision it in CTC.
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
en/us/support/web/tsd-cisco-worldwide-contacts.html
your country.
PWR-FAIL-A
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Equipment Power Failure at Connector A alarm occurs when there is no power supply from the main
power connector to the equipment. This alarm occurs on the electrical interface assemblies (EIA), control
card, or I/O cards.
for more information or log into
to obtain a directory of toll-free Technical Support numbers for
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
PWR-CON-LMT
http://www.cisco.com/c/
367