Error Messages Reference
Error
Error RC16
Error RC17
Error RC18
Error RC19
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
556
Error Message
Probe signal used for calibration
has changed (e.g. channels count
has changed)
Raman gain is lower than managed
minimum
Raman gain is higher than managed
maximum
Force APR is set on Raman Card
Error Messages
Cause/Solution
This is a transient condition. The
number of active channels in the
span has changed during the
calibration. The calibration will be
automatically retried later.
The measured Raman gain is
outside the range managed by the
Raman calibration. Fiber may need
to be replaced. Check the
connectors and losses between
Raman card LINE-RX connector
and transmission fiber input.
Check if APR is forced on the
Raman card.