1.7.242 TX-AIS

For more information about Ethernet cards, refer to the Cisco ONS 15310-CL and Cisco ONS 15310-MA
Note
Ethernet Card Software Feature and Configuration Guide.

Clear the TPTFAIL (CE100T) Alarm

Clear any alarms being reported by the OC-N port on the CE100T-8 circuit.
Step 1
If no alarms are reported by the OC-N port, or if the
Step 2
problem could be on the far-end G-Series Ethernet port. Clear any alarms, such as CARLOSS, reported
against the far-end port or card.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 3
for more information or call Cisco TAC (1 800 553-2447) in order to report a Service-Affecting (SA)
problem.
1.7.242 TX-AIS
The Transmit (TX) Direction AIS condition is raised by the ONS 15310-CL or ONS 15310-MA
backplane when it receives a far-end DS-1 LOS.

Clear the TX-AIS Condition

Step 1
Determine whether there are alarms on the downstream nodes and equipment, especially the
(OCN)" alarm on page
Clear the downstream alarms using the applicable procedures in this chapter.
Step 2
If the condition does not clear, log into the Technical Support Website at
Step 3
http://www.cisco.com/techsupport for more information or call Cisco TAC (1 800 553-2447).

1.7.243 TX-LOF

The Transmit Direction LOF condition is transmitted by the backplane when it receives a DS-1 TX-LOF.
This alarm is raised only at the transmit (egress) side.

Clear the TX-LOF Condition

Complete the
Step 1
Cisco ONS 15310-CL and Cisco ONS 15310-MA Troubleshooting Guide, R7.0
1-142
Default Severity: Not Reported (NR), Non-Service-Affecting (NSA)
SONET Logical Objects: DS1, DS3
1-99, or OOS ports.
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
SONET Logical Objects: DS1, DS3
"Clear the LOF (DS1) Alarm" procedure on page
Chapter 1
"PDI-P" condition on page 1-114
1-87.
Alarm Troubleshooting
is reported, the
"LOS
78-17235-01