Clear the OTDR-ABSOLUTE-R-EXCEEDED-TX Alarm

Clear the OTDR-ABSOLUTE-R-EXCEEDED-TX Alarm
The alarm is cleared automatically when one of the following conditions is satisfied in the last scan:
• The reflectance event causing the alarm disappears.
• The reflectance event in the last scan is below the threshold.
• The absolute threshold check is deactivated.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-BASELINE-A-EXCEEDED-RX
Default Severities: Major (MJ), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Optical Time Domain Reflectometer (OTDR) Baseline Attenuation Threshold Exceeded Rx alarm is
raised when an existing attenuation event in the last scan or a new attenuation event exceeds the baseline
threshold in the Rx direction.
Clear the OTDR-BASELINE-A-EXCEEDED-RX Alarm
The alarm is cleared automatically when one of the following conditions is satisfied:
• The attenuation event causing the alarm disappears.
• The attenuation event is below the threshold.
• The absolute check is activated.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
OTDR-BASELINE-A-EXCEEDED-TX
Default Severities: Major (MJ), Non-Service-Affecting (NSA)
Logical Objects: EQPT
The Optical Time Domain Reflectometer (OTDR) Baseline Attenuation Threshold Exceeded Tx alarm is
raised when an existing attenuation event in the last scan or a new attenuation event exceeds the baseline
threshold in the Tx direction.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
330
http://www.cisco.com/c/en/us/support/index.html