CP-UNVER-CLEARED Alarm

Step 4
Click Apply.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
CP-UNVER-CLEARED Alarm
Default Severity: Minor (MN)
Logical Object: NE
The CP-UNVER-CLEARED alarm is raised under the following conditions:
• When there is a failure in the original path and it is not fixed.
• After all the circuits are moved to the restored path, the port on the original path moves to OOS,DSBLD
The CP-UNVER-CLEARED alarm is automatically cleared after acknowledging the unverified alarms in the
WSON tab.
CTNEQPT-MISMATCH
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: EQPT
The Connection Equipment Mismatch condition is raised when there is a mismatch between the cross-connect
card preprovisioned in the slot and the card actually present in the shelf. For example, an XC-VXL card could
be preprovisioned in Slot 10, but another card could be physically installed.
Note
Cisco does not support configurations of unmatched cross-connect cards in Slot 8 and Slot 10, although this
situation could briefly occur during the upgrade process.
Note
The cross-connect card you are replacing should not be the active card. (It can be in SBY state or otherwise
not in use.)
Note
During an upgrade, this condition occurs and is raised as its default severity, Not Alarmed (NA). However,
after the upgrade has occurred, if you wish to change the condition severity so that it is Not Reported (NR),
you can do this by modifying the alarm profile used at the node. For more information about modifying alarm
severities, refer to the Manage Alarms chapter.
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
162
(ANSI) or Locked,disabled (ETSI) state. These alarms disappear on the original path and unverified