Alarm Troubleshooting

GAIN-LDEG

Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: AOTS
Gain Low Degrade (GAIN-LDEG) alarm is raised on an amplifier card (OPT-BST, OPT-PRE, OPT-AMP-C,
or OPT-AMP-17-C), 40-SMR1-C, or 40-SMR2-C card when the amplifier does not reach the Gain Low
Degrade Threshold. (This value is automatically provisioned with the gain setpoint, but the alarm threshold
is 2 dBm lower than the setpoint.)
Note
This alarm is applicable only when the amplifier working mode is set to Control Gain.
Clear the GAIN-LDEG Alarm
SUMMARY STEPS
1. For the alarmed card, complete the
DETAILED STEPS
For the alarmed card, complete the
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
GAIN-LFAIL
Default Severity: Critical (CR), Service-Affecting (SA)
Logical Object: AOTS
The Gain High Degrade alarm is raised on an amplifier card (OPT-BST, OPT-PRE, OPT-AMP-C, or
OPT-AMP-17-C) when the amplifier does not reach Gain High Degrade Threshold. (This value is automatically
provisioned with the gain setpoint, but the alarm threshold is 5 dBm lower than the setpoint. If the alarm
cannot be cleared, the card must be replaced.
Note
This alarm is applicable only when the amplifier working mode is set to Control Gain.
Clear the GAIN-HDEG Alarm, on page 209
Clear the GAIN-HDEG Alarm, on page 209
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
procedure.
procedure.
http://www.cisco.com/c/en/us/support/index.html
GAIN-LDEG
211