Clear the OPWR-HFAIL Alarm

Clear the OPWR-HFAIL Alarm
SUMMARY STEPS
1. In the amplifier card view, navigate to Provisioning → Optical Line → Parameters tab to check whether
the value of the Transmit Optical Power on the adjacent site is within the limit.
2. If the Transmit Optical Power is too high, check for the OSC PPM mode in network view by navigating
to Provisioning → WDM-ANS → Provisioning tab. Validate if it is correct.
3. Set the OSC PPM mode in the TNCS-O card view by navigating to Provisioning → Line → Ports tab
as per the requirement (LX, SX, ULH, LR2, T, FX, LX_10). Rate may vary the transmit power value
from high power to low power.
4. Check if the alarm clears on the other end.
DETAILED STEPS
In the amplifier card view, navigate to Provisioning → Optical Line → Parameters tab to check whether the value of
Step 1
the Transmit Optical Power on the adjacent site is within the limit.
Step 2
If the Transmit Optical Power is too high, check for the OSC PPM mode in network view by navigating to Provisioning
→ WDM-ANS → Provisioning tab. Validate if it is correct.
Set the OSC PPM mode in the TNCS-O card view by navigating to Provisioning → Line → Ports tab as per the
Step 3
requirement (LX, SX, ULH, LR2, T, FX, LX_10). Rate may vary the transmit power value from high power to low power.
Step 4
Check if the alarm clears on the other end.
There is no threshold value for this alarm on the card to validate and change.
Note
If the alarm does not get cleared, you need to report a Service-Affecting (SA) problem. Log into the Technical Support
Website at
http://www.cisco.com/c/en/us/support/index.html
en/us/support/web/tsd-cisco-worldwide-contacts.html
your country.
OPWR-LDEG
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Objects: AOTS, OCH, OCH-TERM, OMS, OTS
Clear the OPWR-LDEG Alarm
SUMMARY STEPS
1. Complete the
Cisco NCS 2000 series Troubleshooting Guide, Release 11.0
326
to obtain a directory of toll-free Technical Support numbers for
Clear the OPWR-HDEG Alarm, on page 323
for more information or log into
procedure.