Alarm Troubleshooting

Clear the INCOMPATIBLE-SEND-PDIP Alarm

SUMMARY STEPS
1. Reconfigure CTC send PDI-P alarm capability to align with the host node settings.
DETAILED STEPS
Reconfigure CTC send PDI-P alarm capability to align with the host node settings.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
INCOMPATIBLE-SW
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
Logical Object: SYSTEM
The Incompatible Software alarm is raised when CTC cannot connect to the NE due to differing, incompatible
versions of software between CTC and the NE. The alarm is cleared by restarting CTC in order to redownload
the CTC JAR files from the NE.
The INCOMPATIBLE-SW alarm is also raised when CTC nodes in the network have R10.6 packages and
earlier and password policy is greater than 80 characters (127 characters).
Clear the INCOMPATIBLE-SW Alarm
SUMMARY STEPS
1. Restart the CTC application.
DETAILED STEPS
Restart the CTC application.
If the condition does not clear, log into the Technical Support Website at
for more information or call Cisco TAC (1 800 553-2447).
INTRUSION-PSWD
Default Severity: Not Alarmed (NA), Non-Service-Affecting (NSA)
Logical Object: NE