SSCOP Timers

Table 49 and Table 50 present the SSCOP watchdog timers.
Table 49 SSCOP Timers
SSCOP Timer
Poll
Keep-Alive
No-Response
CC
Idle
Table 50 SSCOP Timer Default Values
Param name
Poll
Keep alive
No response
CC
Poll
Keep alive
No response
CC
Idle
For stability, set the timer No-Response > timer Keep-Alive and timer
No-Response > timer Poll should be set. Also set timer No-Response and
timer CC to a value greater than the round trip delay.
Description
The maximum time between transmission of a POLL PDU, when
SD or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
Maximum time between transmission of POLL PDUs, when no
SD or SDP PDUs are queued for transmission or are outstanding
pending acknowledgment.
Maximum time between receipt of a STAT PDU in an active
connection.
The connection control timer determines the time between
transmission of BGN, END, or RS PDUs, as long as an
acknowledgment PDU has not been received.
UNI Standard
UNI 3.0
UNI 3.0
UNI 3.0
UNI 3.0
UNI 3.1
UNI 3.1
UNI 3.1
UNI 3.1
UNI 3.1
Signaling AAL
Default value
(0.1 sec)
5
50
500
50
45
50
350
50
750
365