Update ILMI Channel
Polling Interval
Update and save the ILMI channel polling interval for the specified port in
the CoreBuilder 9000 ATM Enterprise Switch. The minimum value of the
polling interval is 30 seconds. The default ILMI polling value is 30
seconds.
Command Actions
Enter the menu sequence: (1) SYS: Platform configuration
Enter a parameter at the prompt
Parameter
Port ID
Polling interval
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 8 4 4 3.1.2
The following message is displayed:
ILMI polling timeout reconfigured.
The polling timeout of port 3.1.2 is set to 30 seconds and is saved to
flash.
(1) SET: Switch setup
(8) IME: ILMI setup
(4) POL: Polling setup
(4) STO: Set&Save Polling time-out
Format or Range
<slot.group.port>
Range: 30-1800 seconds
1 1 8 4 4 [parameters]
The polling interval for the specified port is updated
and saved.
ILMI polling timeout reconfigured.
30
ILMI Setup
131
Need help?
Do you have a question about the CoreBuilder 9000 and is the answer not in the manual?
Questions and answers