Update Port Interface
Type
Update the Interface Type (NNI, UNI, or GWY) for a specified port of the
CoreBuilder 9000 ATM Enterprise Switch.
Command Actions
Enter the menu sequence: (1) SYS: Platform Configuration
Enter a parameter at the prompt
Parameter
Port number
NNI interface type
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
1 1 3 4 3.1.2 1
The following message is displayed:
This operation will release all connections of the specified
port(s)!
Are you sure (Y/N)?
Enter y to confirm. The following message is displayed:
UNI type was set.
The Interface type for port 3.1.2 is updated to UNI.
(1) SET: Switch Setup
(3) NNI: NNI Setup

(4) SIF: NNI Set Interface Type

Format or Range
<slot.group.port> (0.0 for all ports)
0 to set interface type to NNI
1 to set interface type to UNI
2 to set interface type to GWY
1 1 3 4 [parameters]
The interface type for the specified port is updated.
<type> type was set.