Create Pvc - Quick Setup; Crp: Create Pvc Call - 3Com CoreBuilder 9000 User Manual

Atm enterprise switch
Hide thumbs Also See for CoreBuilder 9000:
Table of Contents

Advertisement

172
C
7: C
HAPTER
ONFIGURING
Create PVC — Quick
Setup
V
C
IRTUAL
HANNELS
Set up PVC using the default for parameters not explicitly set. Default
values for Cell Loss Level, Priority, and Cell Loss Priority are used. (See
Table 23.) The same limits as full PVC call setup apply. For more
information, see "Permanent Virtual Channels" on page 353.
Command Actions
Enter the menu sequence: (3) CON: Connections
Enter a parameter at the prompt
Parameter
Call type
First port number
First port VPI
First port VCI
Second port number
Second port VPI
Second port VCI
Direct access sequence:
Command Result
System action taken:
System message display:
Example
Enter:
3 4 1 1 3 p2p 5.1.1 0 37 5.1.2 0 381
The following message is displayed:
A new PVC was created with call number: 9.
(4) S&C: Setup of Connections and ATM
Addresses
(1) PVC: PVCs Setup
(1) GET: Display VPI/VCI Limits

(3) CRP: Create PVC call

Format or Range
P2P for point-to-point PVC
P2M for point-to-multipoint PVC
<slot.group.port>
See (3)CON\(4)S&C\(1)PVC\(1)GET for VPI/VCI
limits
See (3)CON\(4)S&C\(1)PVC\(1)GET for VPI/VCI
limits
<slot.group.port>
See (3)CON\(4)S&C\(1)PVC\(1)GET for VPI/VCI
limits
See (3)CON\(4)S&C\(1)PVC\(1)GET for VPI/VCI
limits
3 4 1 1 3 [parameters]
A PVC with the required parameters is created.
A new PVC was created with call number:
<n>

Advertisement

Table of Contents
loading