Digital filter for sigma delta modulators (DFSDM)
Figure 80. First conversion for Manchester coding (Manchester synchronization)
External serial clock frequency measurement
The measuring of a channel serial clock input frequency provides a real data rate from an
external Σ∆ modulator, which is important for application purposes.
An external serial clock input frequency can be measured by a timer counting DFSDM
clocks (f
DFSDMCLK
clock after a conversion trigger (regular or injected) and finishes by last input data clock
before conversion ends (end of conversion flag is set). Each conversion duration (time
between first serial sample and last serial sample) is updated in counter CNVCNT[27:0] in
register DFSDM_FLTxCNVTIMR when the conversion finishes (JEOCF=1 or REOCF=1).
The user can then compute the data rate according to the digital filter settings (FORD,
FOSR, IOSR, FAST). The external serial frequency measurement is stopped only if the filter
is bypassed (FOSR=0, only integrator is active, CNVCNT[27:0]=0 in
DFSDM_FLTxCNVTIMR register).