Mitsubishi Electric MELSEC iQ-R Series Programming Manual page 981

Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Precautions
In the following cases, the error completion signal in (d1)+1 is turned on and an error code is stored as the completion status
in the device (d2).
• This instruction is executed during execution of the database access instruction.
• An identification number outside the range is specified by (s1).
• An identification number of a database which is not open is specified by (s1).
• A database built or operated with a programmable controller CPU with firmware version "28" or later is specified by (s1) for
a programmable controller CPU with firmware version earlier than "28".
• The table name to be deleted according to (s2) does not exist.
• The number of characters of the table name specified by (s2) exceeds 32.
• An out-of-range value is specified in (s3) for the deletion condition.
• Database deletion processing failed.
• An out-of-range value is specified in (s3) for the logical operator setting value.
• The logical operator setting value specified by (s3)+35 is 1 or 2, and that in (s3)+1 is set to 0.
• The field name to be set in (s3)+2 is left unset.
• An out-of-range field name is set in the field name specified by (s3)+2 to (s3)+.
Operation error
Error code
Description
(SD0)
2820H
The area specified by (s2), (s3), or (d1) exceeds the applicable range of the device/label used.
For the error code stored in the completion status of the operand, refer to the following.
Page 986 Error codes related to database access instructions
7 APPLICATION INSTRUCTIONS
7.21 Database Access Instructions