Processing details
• These instructions declare the start of a transaction in relation to the database corresponding to the identification number
specified by (s). However, if a data base other than the one specified by (s) is open, the DBTRANS instruction cannot start
a transaction and is completed with an error.
• Upon normal completion, the completion signal in the completion device (d1) is turned on and 0 is stored as the completion
status in the device (d2).
• The following figure shows the operation of the completion device at completion of the DBTRANS(P) instruction.
Program
DBTRANS(P) instruction
Completion device (d1)
OFF
Completion device (d1)+1
OFF
• After a transaction is started by the DBTRANS(P) instruction, the DBCOMMIT(P) instruction needs to be executed to
determine the transaction or the DBROLBAK(P) instruction needs to be executed to restore the state before the start of the
transaction. (If the DBCLOSE(P) instruction is executed before DBCOMMIT(P) or DBROLBAK(P), the transaction is
determined in the status at the execution of the DBCLOSE(P) instruction.)
• SM753 (File being accessed) turns on while the DBTRANS(P) instruction is executed.
DBTRANS(P) instruction cannot be executed. If executed, no processing is performed. However, the instruction has been
completed with an error while the database access instruction is being executed.
• When "To Use or Not to Use the Built-in Database Access" is set to "Use" in the module parameter of the CPU module, the
DBTRANS(P) instruction cannot be executed while SM1498 (CPU module database start-up flag) is off.
processing is performed.
*1 For the firmware versions supporting SM753 and SM1498, refer to the list of special relay areas. ( MELSEC iQ-R CPU Module
User's Manual (Application))
Precautions
In the following cases, the error completion signal in (d1)+1 is turned on and an error code is stored as the completion status
in the device (d2).
• The DBTRANS(P) instruction is executed during execution of the database access instruction.
• An identification number outside the range is specified.
• The DBTRANS(P) instruction is executed while the transaction has already been started.
• A data base other than the one specified by (s) is open.
• The identification number of a database which is not open is specified by (s).
Operation error
Error code
Description
(SD0)
2820H
The area specified by (d1) exceeds the applicable range of the device/label used.
For the error code stored in the completion status of the operand, refer to the following.
Page 986 Error codes related to database access instructions
END processing
END processing
ON
ON
Starting the
transaction
END processing
Error completion
*1
While SM753 is on, the
*1
If executed, no
7 APPLICATION INSTRUCTIONS