7.
8.
Issue 02 (2014-09-30)
--
Total UP/DOWN Session Number : 1/1
Configure bit-error-triggered protection switching.
a.
# Enable bit-error-triggered protection switching for the RSVP-TE tunnel and specify
its reverse tunnel.
# Configure the CSG.
[CSG] interface tunnel 1/0/1
[CSG-Tunnel1/0/1] mpls te bit-error-detection
[CSG-Tunnel1/0/1] mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
2.2.2.2 tunnel-id 100
[CSG-Tunnel1/0/1] mpls te commit
[CSG-Tunnel1/0/1] quit
[CSG] interface tunnel 1/0/2
[CSG-Tunnel1/0/2] mpls te bit-error-detection
[CSG-Tunnel1/0/2] mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
3.3.3.3 tunnel-id 200
[CSG-Tunnel1/0/2] mpls te commit
[CSG-Tunnel1/0/2] quit
# Configure RSG1.
[RSG1] interface tunnel 1/0/1
[RSG1-Tunnel1/0/1] mpls te bit-error-detection
[RSG1-Tunnel1/0/1] mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
1.1.1.1 tunnel-id 100
[RSG1-Tunnel1/0/1] mpls te commit
[RSG1-Tunnel1/0/1] quit
# Configure RSG2.
[RSG2] interface tunnel 1/0/2
[RSG2-Tunnel1/0/2] mpls te bit-error-detection
[RSG2-Tunnel1/0/2] mpls te reverse-lsp protocol rsvp-te ingress-lsr-id
1.1.1.1 tunnel-id 200
[RSG2-Tunnel1/0/2] mpls te commit
[RSG2-Tunnel1/0/2] quit
b.
Configure bit-error-triggered PW switching.
# Configure bit-error-triggered PW switching on the AC interface of the CSG.
[CSG] interface gigabitethernet 1/0/2.10
[CSG-GigabitEthernet1/0/2.10] mpls l2vpn pw bit-error-detection
[CSG-GigabitEthernet1/0/2.10] quit
# Configure bit error detection to trigger PW switchovers on the AC interface of RSG1.
[RSG1] interface eth-trunk 10.1
[RSG1-Eth-Trunk10.1] mpls l2vpn pw bit-error-detection
# Configure bit error detection to trigger PW switchovers on the AC interface of RSG2.
[RSG2] interface eth-trunk 10.1
[RSG2-Eth-Trunk10.1] mpls l2vpn pw bit-error-detection
NOTE
This example shows how to configure bit-error-triggered single-segment (SS)-PW switching. To
configure bit-error-triggered multi-segment (MS)-PW switching, you also need to run the mpls
switch-l2vc ip-address vc-id between ip-address vc-id encapsulation encapsulation-type bit-
error-detection command to enable bit-error-triggered protection switching on superstratum
provider edges (SPEs).
Verify the configuration.
# Run the display bfd bit-error-detection session all command on the CSG to view BFD
bit error information.