Daewoo MATIZ Service Manual page 769

Table of Contents

Advertisement

DAEWOO M-150 BL2
HEATING AND VENTILATION SYSTEM 7A – 19
D108A504
4. Disconnect the control cables from the control as-
sembly.
D Disconnect the temperature control cable (1).
D Disconnect the mode control cable (2).
D Disconnect the recirculating/fresh air door cable
(3).
D108A505
Installation Procedure
1. Connect the control cables to the control assembly.
2. Connect the recirculating/fresh air door cable to the
blower module.
3. Install the glove box to the instrument panel. Refer to
Section 9E, Instrumentation/Driver Information.
4. Connect the temperature control cable and the mode
control cable to the heater module.
5. Connect the electrical connectors.
6. Install the control assembly with the screws.
7. Install the instrument cluster housing trim panel. Re-
fer to Section 9E, Instrumentation/Driver Information.
D108A506
8. Connect the negative battery cable.

Advertisement

Table of Contents
loading

This manual is also suitable for:

My2003

Table of Contents