Daewoo MATIZ Service Manual page 373

Table of Contents

Advertisement

Step
Perform an On-Board Diagnostic (EOBD) System
Check.
1
Is the system check complete?
1. Turn the ignition switch to LOCK.
2. connect the scan tool to the DLC.
2
3. Turn the Turn the ignition switch to ON.
Are any Diagnostic Trouble Codes (DTCs)
displayed?
Refer to the applicable DTC table. Start with the
DTC with the lowest numerical value and move up.
3
Is the DTC identified as valid trouble code P0656?
1. Disconnect the cluster connector
2. Turn the ignition switch to LOCK.
3. Check for an open or short to ground in the wire
4
between the cluster connector terminal C14 and
ground.
Is the problem found?
1. Turn the ignition switch to LOCK.
2. Check for short to battery in the wire between the
5
the cluster connector terminal C14 and ground.
Is the problem found?
1. Change the between cluster and ECM or repair
the connector terminal as needed.
2. Clear any DTCs from ECM.
6
3. Perform the diagnostic system check.
Is the repair complete?
1. Replace the cluster.
2. Clear any DTCs from ECM.
7
3. Perform the diagnostic system check.
Are any Diagnostic Trouble Codes (DTCs)
displayed?
Replace the ECM.
8
Is the replcement complete?
1. Using the scan tool, clear the Diagnostic Trouble
Codes(DTCs)
2. Start the engine and idle at normal operating
temperature.
9
3. Operate the vehicle within the conditions for
setting this DTC as specified in the supporting
text.
Does the scan tool indicate that this diagnostic has
run and passed?
Check if any additional DTCs are set.
10
Are any DTCs displayed that that have not been
diagnosed?
DAEWOO M-150 BL2
DTC P0656 – Fuel Level Gauge Circuit Fault
Action
ENGINE CONTROLS 1F – 275
Value(s)
Yes
Go to Step 2
Go to Step 3
Go to Step 4
Go to Step 6
Go to Step 6
System OK
Go to Step 8
Go to Step 9
Go to Step 10
Go to
applicable DTC
table
No
Go to
"On-Board
Diagnostic
System Check"
Try with
another scan
tool
Go to
applicable DTC
table
Go to Step 5
Go to Step 7
System OK
Go to Step 2
System OK

Advertisement

Table of Contents
loading

This manual is also suitable for:

My2003

Table of Contents