Installing Cable Between The External S Port And Isdn (Ntba) - Auerswald COMpact 5000 Operation Manual

Pbx for analogue/isdn/internet telephony
Hide thumbs Also See for COMpact 5000:
Table of Contents

Advertisement

Note: If the NTBA is relatively far away from the PBX, a cable with wall socket
must first be laid.
1. Insert one end of the ISDN cable into the RJ-45 socket of the external S
2. Insert the other end of the ISDN cable into the RJ-45 socket on the NTBA.
Installing Cable Between the External S
Requirements:
• Inserted COMpact 2BRI module
• Enabled operating mode "S
Note: The default setting is „S
• Terminators enabled at both ends of the connection – in the NTBA and in the PBX on the
external S
port in question
0
• Maximum distance/line length between the devices depending on the connection type:
– Up to 150 m for a PTMP connection
– Up to 1000 m for a PTP connection
• Installation cable (for example, J Y (St) Y 2 x 2 x 0.6) with the following characteristics:
– 4-core
– Unscreened; however: screened for unfavourable conditions, for example, near a
strong transmitter or an electrical power line
– Preferably star quad stranding
Warnung: Power surges, which can occur during electrical storms, can
cause life-threatening electric shocks, or damage or destroy the PBX.
• Hire a qualified electrician to lay the cables within the building.
1. Attach the wires to the four terminal clamps in the NTBA.
COMpact 5000/R - Firmware V6.6A - Installation, Operation and Configuration V05 03/2016
Installing Cable Between the External S
Port and ISDN (NTBA)
0
external" on the S
port in question
0
0
external" for port 1 and „S
0
Installation and Commissioning
Network Provider
Port and ISDN (NTBA)
0
port.
0
internal" for port 2.
0
81