9.28 PBX Configuration—[1-1] Configuration—Slot—Card Property—E1 type
9.28 PBX Configuration—[1-1] Configuration—Slot
—Card Property—E1 type
The properties of the E1 card can be specified.
To adjust related settings, click Line Signal Setting, MFC-R2 Setting 1, and MFC-R2 Setting 2.
Name
Line Coding
Frame Sequence
Frame Option
First Dial Timer
(TIE)
Answer
Detection Timer
Seizure ACK
Wait Timer
LIU Send Option
LIU Receive
Option
RAI Signal
Detection Mode
DTMF Tone—
DTMF Inter-digit
Pause
288
PC Programming Manual
Description
Selects the line coding type of E1 PCM (Pulse
Code Modulation) for the E1 card.
Selects the type of frame sequence for the E1
card.
Selects the value for C-bit and D-bit.
Specifies the minimum time that the PBX waits
after seizing a DDI/DID or TIE line, before
sending the dialled digits to the telephone
company or to another PBX. This allows the
telephone company or the other PBX to have
enough time to accept the dialled digits correctly.
Specifies the length of time required by the PBX
to recognise the answer signal. This allows the
telephone company to have enough time to
accept the dialled digits correctly.
Specifies the length of time that the PBX waits for
the seizure ACK signal.
Indicates the transmitting level (Transmit Pulse
Amplitude) of LIU (reference only).
Selects the receiving level (Receive Equalisation)
of LIU.
Selects the RAI signal detection mode.
Specifies the length of the DTMF inter-digit
pause.
Value Range
HDB3, AMI
PCM30, PCM30-CRC
C=A, D=B; C=0, D=0;
C=0, D=1; C=1, D=0;
C=1, D=1
32 x n (n=1–255) ms
32 x n (n=1–255) ms
0.5 x n (n=1–20) s
Mode 1-Mode 8
Automatic, 6 dB, 12 dB,
18 dB, 24 dB
Type1, Type2
64 + 16 x n (n=0–11)
ms