9.20 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-UTEXT
Name
UT Codec
Priority - 1st—
UT Codec
Priority - 4th
Packet Sampling
Time
Jitter Buffer -
Maximum Delay
Jitter Buffer -
Minimum Delay
Jitter Buffer -
Initial Delay
Gain Type
Remote Place
The settings on this screen are for programming the Simple Remote Connection feature for connecting SIP
phones in remote locations to the PBX. For details and conditions regarding the use of this feature, refer to
"5.2.2.3 Simple Remote Connection" in the Feature Manual.
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Name
Extension
Specifies the extension number
Number
of the port.
Extension
Specifies the extension name of
Name
the port.
Connection
Indicates the port status. To
change the status of the port,
click the desired cell in the
column, and then select INS or
OUS for the port.
This option is only available in
On-line mode.
Phone
Specifies the type of extension
Location
connected to the port.
254
PC Programming Manual
Description
Specifies the priority of the codecs to
be used. None is only available for
2nd, 3rd, and 4th priorities.
Specifies the time interval between
measurements (samples) of sound
data during a conversation. The
smaller this number, the higher the
quality of the transmitted sound.
Specifies the maximum size of the
jitter buffer for voice communications.
Specifies the minimum size of the
jitter buffer for voice communications.
Specifies the initial size of the jitter
buffer for voice communications.
Specifies the type of gain file to
distribute to connected SIP devices.
Description
Value Range
G.722, G711A, G.
729A, G711Mu, None
20 ms, 30 ms, 40 ms
3–50 ms
1–2 ms
1–7 ms
Default, Type1, Type2,
Type3
Value Range
Max. 5 digits (consisting of 0–9)
Max. 20 characters
INS: The port is in service.
OUS: The port is out of service.
Fault: The port is not
communicating with the network.
Local: The extension is located
on the same network as the PBX
(standard configuration).
Remote (SBC): The extension is
accessing the PBX remotely
(Simple Remote Connection).
Remote (MRG): The extension is
accessing the PBX remotely (use
Media Relay Gateway).