9.10 PBX Configuration—[1-1] Configuration—Slot—Port Property—V-SIPGW
3.
Click Execute.
Trunk Adaptor
To connect to a Trunk Adaptor, follow the steps below.
1.
Ensure that the Trunk Adaptor is connected to the network and a power supply, and that all ports to be
set are OUS.
2.
Click Trunk Adaptor. The Trunk Adaptor List screen is displayed.
3.
Enter a name (20 characters or less) for the Trunk Adaptor in Trunk Adaptor Name.
4.
Enter the Trunk Adaptor's IP address in Trunk Adaptor IP Address.
5.
To confirm that the setting is correct, click Connect. If the setting is correct, the Trunk Adaptor's Web
Maintenance Console will open in a new browser window.
For details about the Trunk Adaptor's Web Maintenance Console, refer to the documentation of the
Trunk Adaptor.
6.
Click Next. The Set Trunk Adaptor window will open.
7.
In Virtual SIP Gateway - Port Property - No. Range, specify From and To to select a range of SIP
connections to be used with the Trunk Adaptor. These numbers correspond to the No. column of the
main Port Property screen.
8.
In Name : IP Address, select a name and IP address previously entered on the Trunk Adaptor List
screen.
9.
In SIP Server Port Number, enter the SIP server's port number.
10.
In SIP Account / User Name, enter a 3- to 5-digit number in From.
11.
Click Finish, and the following settings are implemented:
Provider Name and
Trunk Adaptor.
The
User Name and
SIP Account / User Name, increased by 1 for each connection (i.e. if "401" was specified, User
Name and
"402", etc.).
12.
In the Calling Party tab of the V-SIPGW—Port Property screen, set
PBX-CLIP for each port that was set to be used with the Trunk Adaptor.
Main
The Shelf, Slot, and Port for each item are displayed for your reference. For details, see Common
Programming Reference Items in 9.1 PBX Configuration—[1-1] Configuration—Slot.
Name
Connection
202
PC Programming Manual
SIP Server IP Address in the Main tab will be set to match the selected
Authentication ID in the Account tab will be set to the value specified in
Authentication ID for No. 1 will be set to "401", and then for No. 2 they will be set to
Description
Indicates the port status. To
change the status of the port,
click the desired cell in the
column, and then select INS or
OUS for the port.
This option is only available in
On-line mode.
From Header—User Part to
Value Range
INS: The port is in
service.
OUS: The port is out of
service.
Fault: The port is not
communicating with the
network.
Links