Panasonic KX-NS300 Pc Programming Manual page 114

Hybrid ip-pbx
Hide thumbs Also See for KX-NS300:
Table of Contents

Advertisement

7.4.6 Utility—Monitor/Trace—UM System Trace (Internal)
7.4.6 Utility—Monitor/Trace—UM System Trace (Internal)
Unified Messaging (UM) system processes can be monitored and logged.
This screen can be accessed only in On-line mode.
The following data can be traced and logged for each UM port, or all UM ports:
DTMF / Dial: data regarding DTMF signals received by the Unified Messaging system.
Guidance: guidance data that the Unified Messaging system played.
Message: Unified Messaging system activity for messages such as creating, playing and deleting.
Process Event: events occurred between Unified Messaging system processes such as Application, Call
Processor and DSP.
Caller ID: received Caller ID information.
DID: received DID numbers.
PIN: PINs received by the Unified Messaging system.
Follow the steps below to monitor or log the system trace data.
1.
Select Internal Trace, Display, or Trace Clear.
Setting
1.
Check Enable / Disable Trace Data.
2.
Check the data and UM ports you wish to monitor.
3.
Click OK.
Display: Displays the trace data and/or error data.
1.
Check the data and UM ports you wish to monitor.
2.
To include error data, click the Error Trace tab and check Error Data.
3.
Click OK.
4.
The selected data will be displayed in a new window. Click the Trace Data or Error Trace tabs
to switch views. Click Save Log File to save a copy of the displayed data.
5.
Click Cancel when finished.
Trace Clear: Clears saved trace data.
1.
Select the trace data to clear.
2.
Click OK to clear the selected trace data.
3.
The message "System Trace Clear Successful" will be displayed. Click OK to continue.
7.4.7 Utility—Monitor/Trace—E1 Signalling Bit Monitor
Displays reference signalling bit information for all channels of a E1 card that is installed in an Expansion
Unit by monitoring sent and received A, B, C and D bits. This utility is intended for use by dealers.
For information about Expansion Units see 9.33 PBX Configuration—[1-1] Configuration—Slot—
Expansion Unit1/Expansion Unit2/Expansion Unit3.
This option is only available at the Installer level, and requires that the target card be set to INS status.
While monitoring is being performed, any displayed bits whose value changes from 0 to 1 or vice versa will
be highlighted in red until the next screen refresh is performed.
To view signalling bit information
1.
From the Shelf-Slot No. drop-down list, select the target slot. Each card will be preceded by the pattern
"X-Y" as follows:
X: Shelf number (1-4)
114
PC Programming Manual

Advertisement

Table of Contents
loading

Table of Contents