CHAPTER 14 8/10-BIT A/D CONVERTER
14.4.3

A/D Control Status Register (ADCS)

The A/D control status register has features to suspend and confirm conversion, enable/
disable interrupt requests, confirm the status of interrupt requests, and select the A/D
conversion resolution.
■ A/D Control Status Register (ADCS: ADCS0 to ADCS2)
00007C
H
000084
H
00008C
H
Read/Write →
Initial value →
R/W: Readable/Writable
W: Write only
: Initial value
336
Bit15
Bit14
Bit13
BUSY
INT
INTE
R/W
R/W
R/W
(0)
(0)
(0)
INT
0
1
BUSY
0
Now stop A/D conversion
1
Now A/D converting
Bit12
Bit11
Bit10
PAUS
S10
-
R/W
R/W
-
(0)
(0)
(X)
A/D conversion start bit
START
(Only enable at software starting)
0
A/D conversion function is not starting.
1
A/D conversion function is starting.
S10
A/D conversion resolution selection bit
0
10-bit resolution (D9 to D0)
1
8-bit resolution (D7 to D0)
PAUS
Halt flag bit
0
Generate no halting of A/D conversion operation
1
Halt on A/D conversion operation
INTE
Interrupt request enable bit
0
Interrupt request output is disabled.
1
Interrupt request output is enabled.
Interrupt request flag bit
At read
No A/D conversion ends Bit clear
A/D conversion ends
A/D converting bit
At read
Bit9
Bit8
START
-
W
-
(0)
(0)
At write
No change, no impact to others.
At write
A/D conversion forcibly stops
No change, no impact to others.