Define the standard Entry Queue parameters (as described in
Chapter 3).
4
In the Cascade field, select Master or Slave depending on the Master/
Slave relationship.
— Set this field to Master if the Entry Queue is defined on the MCU
that is at the center of the topology and other conferences dial
into it (acting as the Master).
— Set this field to Slave if the Entry Queue is defined on the MCU
acting as a Slave, that is, to which the link from the Master MCU
(MCU at the center of the topology) is dialing.
If you are defining an HD cascaded Entry Queue, it is recommended
to select the same Profile that is selected for both conferences.
5
Click OK.
The new Entry Queue enabling cascading is created.