Modifications to the Master MCU Requiring System Reset
Table 19-20
Hot Backup
Field
Synchronization
Status
3
Click OK.
Modifications to the configuration of the Master MCU that require a
System Reset cannot be performed while Hot Backup is enabled.
To modify the Master MCU configuration:
1
Disable the Hot Backup on the Master and Slave MCUs.
2
Modify the Master MCUs configuration.
3
Reset the Master MCU.
4
When the reset is complete, enable Hot Backup on the Master and Slave
MCUs.
5
If required, reset the Slave MCU.
Polycom RMX 1500/2000/4000 Administrator's Guide
Description
The status of the synchronization between the Master
and Slave MCUs in the Hot Backup configuration is
indicated as:
•
OK - Hot Backup is functioning normally, and the
Master and Slave MCUs are synchronized.
•
Attempting - Hot Backup is attempting to
synchronize the Master and Slave MCUs.
•
Fail - A failure occurred while trying to synchronize
the paired MCUs.
•
None - Hot Backup has not been enabled.
19-101