Appendix C-CDR Fields - Unformatted File

Event Specific Fields

C-16
The following tables describe the fields which are specific to each type of
event.
Some fields that were supported by the MGC Manager, are not supported by the
RMX 1500/2000/4000. In addition, for some fields the RMX 1500/2000/4000 has
a fixed value, whereas the MGC Manager supported multiple values. For more
information about the MGC Manager fields and values, see the MGC Manager
User's Guide Volume II, Appendix A.
Table C-3
Event Fields for Event 1 - CONFERENCE START
Field
Dial-Out Manually
Auto Terminate
Line Rate
Description
Indicates whether the conference was a dial-out
manually conference or not.
Currently the only value is:
0 - The conference was not a dial-out manually
conference, that is, the MCU initiates the communication
with dial-out participants, and the user does not need to
connect them manually.
Indicates whether the conference was set to end
automatically if no participant joins the conference for a
predefined time period after the conference starts, or if
all participants disconnect from the conference and the
conference is empty for a predefined time period.
Possible values are:
0 - The conference was not set to end automatically.
1 - The conference was set to end automatically.
The conference line rate, as follows:
0 - 64 kbps
6 - 384 kbps
12 - 1920 kbps
13 - 128 kbps
15 - 256 kbps
23 - 512 kbps
24 - 768 kbps
26 - 1152 kbps
29 - 1472 kbps
32 - 96 kbps