SSE-G2252/SSE-G2252P Switches User's Manual
Syntax
[no] snmp-server notify-filter profile-name remote ip-address
profile-name - Notification log profile name. (Range: 1-32 characters)
ip-address - The Internet address of a remote device. The specified target host must
already have been configured using the
NOTE: The notification log is stored locally. It is not sent to a remote device.
This remote host parameter is only required to complete mandatory fields in the
SNMP Notification MIB.
Default Setting
None
Command Mode
Global Configuration
Command Usage
Systems that support SNMP often need a mechanism for recording Notification
information as a hedge against lost notifications, whether those are Traps or Informs
that exceed retransmission limits. The Notification Log MIB (NLM, RFC 3014)
provides an infrastructure in which information from other MIBs may be logged.
Given the service provided by the NLM, individual MIBs can now bear less
responsibility to record transient information associated with an event against the
possibility that the Notification message is lost, and applications can poll the log to
verify that they have not missed any important Notifications.
If notification logging is not configured and enabled, when the switch reboots, some
SNMP traps (such as warm start) cannot be logged.
To avoid this problem, notification logging should be configured and enabled using
the snmp-server notify-filter command and
stored in the startup configuration file. Then when the switch reboots, SNMP traps
(such as warm start) can now be logged.
When this command is executed, a notification log is created (with the default
parameters defined in RFC 3014). Notification logging is enabled by default (see the
nlm
command), but will not start recording information until a logging profile
specified with this command is enabled with the
Based on the default settings used in RFC 3014, a notification log can contain up to
256 entries, and the entry aging time is 1440 minutes. Information recorded in a
notification log, and the entry aging time can only be configured using SNMP from a
network management station.
snmp-server host
nlm
command, and these commands
nlm
command.
22-20
command.