Ip Igmp Snooping Unsolicited-Report-Interval - Supermicro SSE-G2252 User Manual

52-port layer 2 gigabit ethernet switch / with 48 poe-capable ports
Hide thumbs Also See for SSE-G2252:
Table of Contents

Advertisement

ip igmp snooping unsolicited-report-interval

This command specifies how often the upstream interface should transmit unsolicited
IGMP reports when proxy reporting is enabled. Use the no form to restore the default
value.
Syntax
ip igmp snooping unsolicited-report-interval seconds
no ip igmp snooping version-exclusive
seconds - The interval at which to issue unsolicited reports. (Range: 1-65535
seconds)
Default Setting
400 seconds
Command Mode
Global Configuration
Command Usage
When a new upstream interface (that is, uplink port) starts up, the switch sends
unsolicited reports for all currently learned multicast channels out through the new
upstream interface.
This command only applies when proxy reporting is enabled (see
proxy-reporting" on page
Example
SSE-G2252(config)#ip igmp snooping unsolicited-report-interval 5
SSE-G2252(config)#
Chapter 38: Multicast Filtering Commands
38-4).
38-11
"ip igmp snooping

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sse-g2252p

Table of Contents