Tc-Flush-Standard - Dell Force10 Z9000 Reference Manual

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

attack. This option places the port into an Error Disable state if a BPDU appears and a message
is logged so that the administrator can take corrective action.
If you do not enable shutdown-on-violation, BPDUs are still sent to the RPM CPU.
You cannot enable STP root guard and loop guard at the same time on a port. For example, if
you configure loop guard on a port on which root guard is already configured, the following
error message displays: % Error: RootGuard is configured. Cannot
configure LoopGuard.
Enabling Portfast BPDU guard and loop guard at the same time on a port results in a port that
remains in a Blocking state and prevents traffic from flowing through it. For example, when
Portfast BPDU guard and loop guard are both configured:
Example
FTOS(conf)#interface gigabitethernet 4/0
FTOS(conf-if-gi-4/0)#spanning-tree rstp edge-port
FTOS(conf-if-gi-4/0)#show config
!
interface GigabitEthernet 4/0
FTOS#

tc-flush-standard

Enable the MAC address flushing after receiving every topology change notification.
C-Series, E-Series, S-Series, Z-Series, S4810
Syntax
tc-flush-standard
To disable, use the no tc-flush-standard command.
Defaults
Disabled
Command Modes
CONFIGURATION
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.6.1.0
NOTE: A port configured as an edge port, on an RSTP switch, immediately transitions to
the Forwarding state. You should only configure ports connected to end-hosts as edge
ports. Consider an edge port similar to a port with a spanning-tree portfast
enabled.
If a BPDU is received from a remote device, BPDU guard places the port in an Err-
Disabled Blocking state and no traffic is forwarded on the port.
If no BPDU is received from a remote device, loop guard places the port in a Loop-
Inconsistent Blocking state and no traffic is forwarded on the port.
no ip address
switchport
spanning-tree rstp edge-port
no shutdown
Introduced on the Z9000.
Introduced on the S4810.
Introduced on the S-Series.
1283

Advertisement

Table of Contents
loading

Table of Contents