Snmp-Server Engineid - Dell Force10 Z9000 Reference Manual

Ftos command line reference guide for the z9000 system ftos 9.1.(0.0)
Hide thumbs Also See for Force10 Z9000:
Table of Contents

Advertisement

snmp-server engineID

Configure the name for both the local and remote SNMP engines on the router.
C-Series, E-Series, S-Series, Z-Series
Syntax
snmp-server engineID [local engineID] [remote ip-address udp-
port port-number engineID]
To return to the default, use the no snmp-server engineID [local engineID]
[remote ip-address udp-port port-number engineID] command.
Parameters
local
remote
address
udp-port
number engineID
Defaults
As above.
Command Modes
CONFIGURATION
Command History
Version 8.3.11.1
Version 8.3.7.0
Version 7.6.1.0
Version 7.5.1.0
E-Series legacy
command
Usage
Changing the value of the SNMP Engine ID has important side effects. A user's password
Information
(entered on the command line) is converted to an message digest algorithm (MD5) or secure
hash algorithm (SHA) security digest. This digest is based on both the password and the local
Engine ID. The command line password is then destroyed, as required by RFC 2274. Because of
this deletion, if the local value of the Engine ID changes, the security digests of SNMPv3 users
will be invalid and the users will have to be reconfigured.
For the remote Engine ID, the host IP and UDP port are the indexes to the command that are
matched to either overwrite or remove the configuration.
Related
show snmp engineID
Commands
configured on the router.
engineID
Enter the keyword local followed by the engine ID number that
identifies the copy of the SNMP on the local device.
Format (as specified in RFC 3411): 12 octets.
ip-
Enter the keyword remote followed by the IP address that identifies
the copy of the SNMP on the remote device.
port-
Enter the keywords udp-port followed by the user datagram
protocol (UDP) port number on the remote device. The range is 0 to
65535. The default is 162.
Introduced on the Z9000.
Introduced on the S4810.
Introduced on the S-Series.
Introduced on the C-Series.
– displays the SNMP engine and all the remote engines that are
The first four octets are set to the private enterprise number.
The remaining eight octets are the MAC address of the
chassis.
1369

Advertisement

Table of Contents
loading