Motorola MPC533 Reference Manual page 982

Table of Contents

Advertisement

Program Trace
Previous Address (A1) = 0x0003 FC01, New Address (A2) = 0x0003 F365
Address Message (M1) = 1111 0110 0100
+
A1
Figure 22-32. Relative Address Generation and Re-Creation
22.3.3
Queue Overflow Program Trace Error Message
A trace overrun error occurs when a trace message cannot be queued due to the queue being
full, provided program trace is enabled.
The overrun error causes the message queue to be flushed, and an error message to be
queued. The error code within the error message indicates that either a
program/data/ownership trace overrun error has occurred or that only a program trace
overrun has occurred. The next BTM will be a synchronization message. Refer to
Table 22-20.
The error message has the following format:
Figure 22-33. Error Message (Queue Overflow) Format
22-50
PRELIMINARY—SUBJECT TO CHANGE WITHOUT NOTICE
Message Generation:
A1 = 0000 0000 0000 0011 1111 1100 0000 0001
+
A2 = 0000 0000 0000 0011 1111 0011 0110 0101
M1 = 0000 0000 0000 0000 0000 1111 0110 0100
Address Re-Creation:
M1 = A2
A1 = 0000 0000 0000 0011 1111 1100 0000 0000
+
M1 = 0000 0000 0000 0000 0000 1111 0110 0100
A2 = 0000 0000 0000 0011 1111 0011 0110 0101
[6 bits]
TCODE (8)
Length = 11 bits
MPC533 Reference Manual
[5 bits]
Error Code (0b0 0000,
0b0 0001, 0b0 0010,
0b0 0111)
MOTOROLA