Vertiv NetSure LMS1000 User Manual page 490

Lms data processing unit
Table of Contents

Advertisement

RETRIEVE-PERFORMANCE MONITORING
(RTRV-PM-{EQPT|ALL})
Referenced In: TR-NWT-000833, Issue 5, pg. 4-307
General Description: Instructs LMS1000 to send its current set of Performance Monitoring (PM) data
associated with one or more equipment units, facilities, etc. within LMS1000.
Parameters are provided to retrieve past PM data for LMS1000s that can store a history of performance
monitoring information.
The TL1 command language allows for reporting of Performance Monitoring information, enabling/disabling of
these reports, and scheduling of these reports. In addition, the TL1 commands for Performance Monitoring can
specify the equipment unit(s) on which performance monitoring is to be done. LMS1000 does not currently
have these types of capabilities for statistical information.
Related Commands: None
LMS1000 Access Level: 1
LMS1000 Equivalent: STATS
LMS1000 Input Format Variations:
<aid>
Use of the command code modifier ALL causes retrieval of Performance Monitoring (PM) data for all access
identifiers of the proper type. If the command code modifier is ALL, the value of the access identifier parameter
must be ALL. A NULL value is not permitted for this parameter. Invalid values received for this parameter
return an error response with the error code IIAC.
<montype>
Specifies the type of monitored parameter for which a value is requested. This parameter is not supported by
LMS1000. The only valid value for this parameter is ALL. An ALL value for this parameter requests all types of
monitored parameters be retrieved. Invalid values received for this parameter return an error response with the
error code IDNV.
<monlev>
Specifies the discriminating level for the requested monitored parameter. This parameter is not supported by
LMS1000. The only valid value for this parameter is NULL. A NULL value causes the parameter to default to 1-
UP. Invalid values for this parameter return an error response with the error code IDNV.
<locn>
This parameter does not apply to LMS1000. The only valid value for this parameter is NULL. Invalid values for
this parameter return an error response with the error code IDNV.
<dirn>
This parameter does not apply to LMS1000. The only valid value for this parameter is NULL. Invalid values
received for this parameter return an error response with the error code IDNV.
<tmper>
Vertiv™