Vertiv NetSure LMS1000 User Manual page 199

Lms data processing unit
Table of Contents

Advertisement

SET NETSURE LVD<n<t>> FORCECONN
SET NETSURE LVD RECONNECT
SET NETSURE MESSAGE MCA
SET NETSURE MESSAGE PCU<n>
SET NETSURE PASSWORD
SET NETSURE PCU FANSPEED
SET NETSURE PCU LOADSHARE
SET NETSURE PCU STATE<n>
SET NETSURE SYSTEM AUTOEQMULT
SET NETSURE SYSTEM BATONDISCH
SET NETSURE SYSTEM 50%BATONDISCH
SET NETSURE SYSTEM BATTOVRCUR
SET NETSURE SYSTEM BATTCURLIM
SET NETSURE SYSTEM CALVOLT
SET NETSURE SYSTEM COMPSLOPE
SET NETSURE SYSTEM COMPMAX
SET NETSURE SYSTEM COMPMIN
SET NETSURE SYSTEM COMPSOURCE
SET NETSURE SYSTEM CURLIMIT
SET NETSURE SYSTEM FACTORYCAL
SET NETSURE SYSTEM FLTVOLT
SET NETSURE SYSTEM HIVLTALM1
SET NETSURE SYSTEM HIVLTALM2
SET NETSURE SYSTEM HVS
SET NETSURE SYSTEM INVENTORY
SET NETSURE SYSTEM MODE
SET NETSURE SYSTEM NAGTIMER
SET NETSURE SYSTEM OVRCURRENT
SET NETSURE SYSTEM RLYTESTTIME
SET NETSURE SYSTEM TEMPCOMP
SET NETSURE SYSTEM TEMPHIGH<n>
SET NETSURE SYSTEM TEMPLOW<n>
SET NETSURE SYSTEM TSTEQVOLT
SET NETSURE SYSTEM TSTEQTIME
SET NETSURE SYSTEM 25APLACES
SET NETSURE SYSTEM 50APLACES
SET NETSURE SYSTEM 100APLACES
SET NETSURE SYSTEM 200APLACES
SET NETSURE SUBSYSTEM CALVOLT
SET NETSURE SUBSYSTEM FACTORYCAL
SET NETSURE SUBSYSTEM HIVALM
SET NETSURE SUBSYSTEM LVALM
SET NETSURE SUBSYSTEM OVRCURRENT
UPLOAD NETSURE
UPLOAD TFTP NETSURE
Vertiv™
| NetSure™ LMS Data Processing Unit User Manual (Section 5847) | Rev. ZA
Manually reconnect specified LVD
set LVD reconnect voltage setting
set MCA custom message
set specified PCU custom message
set MCA logon password
configure PCU fan speed
configure PCU Load share alarm
turn specified PCU On or Off
set Auto Equalize Multiplier
set system Battery On Discharge alarm
set system 50% Battery On Discharge alarm
set Battery Charge Alarm
set Battery Recharge Current Limit
set system calibration voltage
set Digital Temperature Comp. Slope
set Digital Temp. Comp. Max voltage
set Digital Temp. Comp. Min voltage
configure Digital Temp. Comp. source
set system current limit
set system cal. voltage to factory default
set system float voltage
set system High Voltage 1 Alarm
set system High Voltage 2 Alarm
set system High Voltage Shutdown
reset the system equipment inventory
set Power System mode
set system ACO timer
set system Overcurrent alarm
set Relay Test Time
set system Temperature compensation voltage
set Temp. Probe High alarm
set Temp. Probe Low alarm
set system test/equalize voltage
set system test/equalize timeout
set system number of 25A Places
set system number of 50A Places
set system number of 100A Places
set system number of 200A Places
set subsystem calibration voltage
set subsystem cal. voltage to factory default
set subsystem High Voltage alarm
set subsystem Low Voltage alarm
set subsystem Overcurrent alarm
configure VPS/NPS Power System by uploading
file using XMODEM protocol
configure VPS/NPS Power System by uploading
199