Vertiv NetSure LMS1000 User Manual page 193

Lms data processing unit
Table of Contents

Advertisement

TRAPS RETIRED
TRAPS VERSION <V1|V2>
ALARMS NETSURE
ALARMS NETSURE LVD
ALARMS NETSURE MCA
ALARMS NETSURE PCU<n>
ALARMS NETSURE SHUNT
ALARMS NETSURE SUBSYSTEM
ALARMS NETSURE SYSTEM
DOWNLOAD NETSURE
DOWNLOAD TFTP NETSURE
PRCONFIG NETSURE
PRCONFIG NETSURE INVENTORY
PRCONFIG NETSURE SETTINGS
SCAN NETSURE
SCAN NETSURE LVD
SCAN NETSURE MCA
SCAN NETSURE PCU<n>
SCAN NETSURE SUBSYSTEM
SCAN NETSURE SYSTEM
SET NETSURE INTERFACE
SET NETSURE LVD<n<t>> DISCONNECT
SET NETSURE LVD<n<t>> FORCECONN
SET NETSURE LVD RECONNECT
SET NETSURE MESSAGE MCA
SET NETSURE MESSAGE PCU<n>
SET NETSURE PASSWORD
SET NETSURE PCU FANSPEED
SET NETSURE PCU LOADSHARE
SET NETSURE PCU STATE<n>
SET NETSURE SYSTEM AUTOEQMULT
SET NETSURE SYSTEM BATONDISCH
SET NETSURE SYSTEM 50%BATONDISCH
SET NETSURE SYSTEM BATTOVRCUR
SET NETSURE SYSTEM BATTCURLIM
SET NETSURE SYSTEM CALVOLT
SET NETSURE SYSTEM COMPSLOPE
SET NETSURE SYSTEM COMPMAX
SET NETSURE SYSTEM COMPMIN
Vertiv™
| NetSure™ LMS Data Processing Unit User Manual (Section 5847) | Rev. ZA
disable/enable the system's ability to send SNMP Retired
Alarm TRAPS
change the version of SNMP TRAPs sent by the system
list active VPS/NPS Power System alarms
list active LVD alarms
list active MCA alarms
list active PCU alarms
list active SHUNT alarms
list active subsystem type alarms
list active system type alarms
dump VPS/NPS Power System configuration
using XMODEM protocol
dump VPS/NPS Power System configuration
using TFTP
list VPS/NPS Power System settings
and equipment inventory
list VPS/NPS Power System equipment inventory
list VPS/NPS Power System settings
list present status of VPS/NPS Power System
list present status of LVD circuits
list present status of MCA
list present status of specified PCU
list present status of subsystem data
list present status of system data
Enable/Disable VPS/NPS interface
set specified LVD disconnect voltage settings
Manually reconnect specified LVD
set LVD reconnect voltage setting
set MCA custom message
set specified PCU custom message
set MCA logon password
configure PCU fan speed
configure PCU Load share alarm
turn specified PCU On or Off
set Auto Equalize Multiplier
set system Battery On Discharge alarm
set system 50% Battery On Discharge alarm
set Battery Charge Alarm
set Battery Recharge Current Limit
set system calibration voltage
set Digital Temperature Comp. Slope
set Digital Temp. Comp. Max voltage
set Digital Temp. Comp. Min voltage