Vertiv NetSure LMS1000 User Manual page 194

Lms data processing unit
Table of Contents

Advertisement

SET NETSURE SYSTEM COMPSOURCE
SET NETSURE SYSTEM CURLIMIT
SET NETSURE SYSTEM FACTORYCAL
SET NETSURE SYSTEM FLTVOLT
SET NETSURE SYSTEM HIVLTALM1
SET NETSURE SYSTEM HIVLTALM2
SET NETSURE SYSTEM HVS
SET NETSURE SYSTEM INVENTORY
SET NETSURE SYSTEM MODE
SET NETSURE SYSTEM NAGTIMER
SET NETSURE SYSTEM OVRCURRENT
SET NETSURE SYSTEM RLYTESTTIME
SET NETSURE SYSTEM TEMPCOMP
SET NETSURE SYSTEM TEMPHIGH<n>
SET NETSURE SYSTEM TEMPLOW<n>
SET NETSURE SYSTEM TSTEQVOLT
SET NETSURE SYSTEM TSTEQTIME
SET NETSURE SYSTEM 25APLACES
SET NETSURE SYSTEM 50APLACES
SET NETSURE SYSTEM 100APLACES
SET NETSURE SYSTEM 200APLACES
SET NETSURE SUBSYSTEM CALVOLT
SET NETSURE SUBSYSTEM FACTORYCAL
SET NETSURE SUBSYSTEM HIVALM
SET NETSURE SUBSYSTEM LVALM
SET NETSURE SUBSYSTEM OVRCURRENT
UPLOAD NETSURE
UPLOAD TFTP NETSURE
Programmed Command:
where:
<>
anything enclosed in brackets is optional
n
is a valid number
t
is a type A, B, E, F, G, L, R for Analog, Binary,
Energy Management, Function, Group, LED or Relay
is A or B for VPS/NPS LVD settings
Command<6>: HELP
ACK
ACO
AID <n>
ALARMS
ANSWER
BATTERY
BOARDS
BYE
Vertiv™
| NetSure™ LMS Data Processing Unit User Manual (Section 5847) | Rev. ZA
configure Digital Temp. Comp. Source
set system current limit
set system cal. voltage to factory default
set system float voltage
set system High Voltage 1 Alarm
set system High Voltage 2 Alarm
set system High Voltage Shutdown
reset the system equipment inventory
set Power System mode
set system ACO timer
set system Overcurrent alarm
set Relay Test Time
set system Temperature compensation voltage
set Temp. Probe High alarm
set Temp. Probe Low alarm
set system test/equalize voltage
set system test/equalize timeout
set system number of 25A Places
set system number of 50A Places
set system number of 100A Places
set system number of 200A Places
set subsystem calibration voltage
set subsystem cal. voltage to factory default
set subsystem High Voltage alarm
set subsystem Low Voltage alarm
set subsystem Overcurrent alarm
configure VPS/NPS Power System by uploading
file using XMODEM protocol
configure VPS/NPS Power System by uploading
file using TFTP
Command Strings:
acknowledge report type alarms
list alarms that have been cutoff
display configured access identifiers
list active alarms
show number of rings before the system answers
BATTERY type commands
list installed boards
logoff and hangup