8.
Other functionality
Even mark function
Waveform search
function
Jump function
Cursor measurement
function
Scaling function
Comment entry
function
Start state retention
function
Startup auto-
measurement
function
Find Quality Products Online at:
Even mark entry
Assigns event marks when one of the following events occurs.
method
(1) Pressing the
(2) With
(3) Inputting a signal to an external input terminal
(4) If an alarm is outputted (can be toggled between on and
Number of inputs
Up to 1000 inputs per measurement
Search waveforms and display target location in the center of the waveform screen.
Search conditions
Search by choosing level, window, maximum value, minimum
value, local maximum value, or local minimum value.
Search range
All data in the internal buffer memory or data between the A/B
cursors (on the vertical axis)
Search targets
Analog, pulse, logic, waveform calculations
Specify the event mark, A/B cursor position, trigger point, or waveform display position to
display in the center of the waveform screen.
Cursor display
All channels or specified channels (user-selectable)
Cursor movement
A, B, or simultaneous (user-selectable)
Types of cursors
Vertical or horizontal (user-selectable)
Vertical
Display of the following values:
• Times at the A and B cursors
• Measured values at the A and B cursors
• Time lag between the A and B cursors
• Reciprocals of the time lags (frequencies) between any two
points selected from among the trigger point, A cursor, and B
cursor
• Differences in measured values between the A and B cursors
Horizontal
Display of the following values acquired across the selected
channels:
• Values at the A and B cursor
• Difference between values at the A and B cursors
Scaling settings can be configured separately for each channel.
Analog
Set by conversion rate, by 2 points, by strain gage rating (Strain
Unit only), or by sensitivity (user-selectable)
Pulse (integration)
Set by physical value per pulse or number of pulses per physical
value (user-selectable)
Pulse (rotational
Set by conversion rate or by 2 points (user-selectable)
speed)
Temperature display in
When display language is set to English, Fahrenheit
degrees Fahrenheit
temperature scaling is available.
Enter titles and channel-specific comments (values, alphabetical characters, and
symbols).
On/Off (user-selectable)
When enabled, the system will enter the re-start state and automatically start recording if
the power is turned off during recording and then turned back on (or the trigger standby
state if using a trigger).
On/off (user-selectable)
When the function is enabled, the instrument will automatically start measurement on
startup (get into the trigger standby state when the trigger setting is enabled)
GlobalTestSupply
www.
START
key
[Mark]
chosen on the screen, pressing the
key.
off).
.com
ENTER
307