Example Trigger Settings - Hioki MEMORY HiLOGGER LR8450 Instruction Manual

Hide thumbs Also See for MEMORY HiLOGGER LR8450:
Table of Contents

Advertisement

2.9 Example Trigger Settings

This section introduces some example trigger settings.
Capture data from the time the
pressed.
Capture data once for 1 min. starting from when the
Capture data for 1 min. repeatedly starting from when the
60 min. elapses.
Capture data starting when the
temperature exceeds 500°C.
Once the CH1 measured temperature exceeds 500°C, capture data until the
pressed.
Once the CH1 measured temperature exceeds 500°C, capture data until the temperature
falls below 300°C.
Once the CH1 measured temperature exceeds 500°C, capture data repeatedly until the
temperature falls below 300°C.
Once the CH1 measured temperature exceeds 500°C, capture data for the next 1 min.
Capture data for 1 min. before and after the CH1 measured temperature exceeds 500°C.
Capture data from 9:00 am to 5:00 pm on June 17, 2020.
Capture data 24 hours every day for one month starting at 9:00 am on June 17, 2020.
Capture data from 9:00 am to 5:00 pm every day for one month starting on June 17, 2020.
Capture one hour of data at 9:00 am, 3:00 pm, 9:00 pm, and 3:00 am for one month
starting on June 17, 2020.
No. Measurement start Measurement stop
1
2
3
4
5
6
7
8
9
10
2020-6-17 9:00
11
2020-6-17 9:00
12
2020-6-17 9:00
13
2020-6-17 9:00
Find Quality Products Online at:
What you want to do
START
key is pressed until the time the
START
key is pressed until the CH1 measured
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Manual
Time
Time
2020-6-17 17:00
Time
Time
2020-7-17 9:00
Time
Time
2020-7-17 9:00
Time
Time
2020-7-17 9:00
GlobalTestSupply
www.
STOP
START
key is pressed.
START
key is pressed until
Recording start
Recording stop
Specified time
1 min.
Specified time 1 h
Stop trigger
↑ 500°C
Start trigger
↑ 500°C
Start trigger
Stop trigger
↑ 500°C
↓ 300°C
Same as above
Same as above
Start trigger
Specified time
↑ 500°C
1 min.
Same as above
Same as above
Interval trigger
Specified time
1 day
8 h
Interval trigger
Specified time
6 h
1 h
.com
See
(in table below)
key is
No. 1
No. 2
No. 3
No. 4
STOP
key is
No. 5
No. 6
No. 7
No. 8
No. 9
No. 10
No. 11
No. 12
No. 13
Other
File splitting 1 min.
Repetitive recording
Pre-trigger 1 min.
File splitting 1 day
Repetitive recording
Repetitive recording
sales@GlobalTestSupply.com

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEMORY HiLOGGER LR8450 and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Memory hilogger lr8450-01Lr8450Lr8450-01

Table of Contents